PFM920I-6UN-C

UTP CAT6 Cable

> 305 m (1000 ft)/carton UTP CAT6, power over Ethernet, compatible with one cable

> High-purity oxygen-free copper conductor

> Customized PVC outer sheath; CE CPR Eca flame retardant class certified

> 10-year warranty

Categories: , Tag: Our Brands

Description

Conductor

Material

Oxygen free copper (99.97% purity)

Diameter

0.53 mm ± 0.01 mm

Insulation

Material

HDPE

Min. Average Thickness

0.21 mm

Diameter

0.95 mm ± 0.1 mm

Color (4 Pairs)

Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown

Separator

Material

PE

Specification

Translucent 4.5 × 0.4 mm

Rip Cord

Material

Polyester

Specification

500D

Sheath

Material

PVC

Min. Average Thickness

0.5 mm

Diameter

6.0 mm ± 0.3 mm

Color

White

Electrical

Max. DC Resistance of a Single Conductor

8.7Ω/100 m

Min. Insulation Resistance

5000MΩ·km

Max. DC Resistance Unbalance

2% (pair intra), 4% (pairs inter)

Dielectric Strength

No breakdown with 1KV DC for 1 min

Transmission

Characteristic Impedance

100 ± 15Ω

Near End Cross Talk

≥39.30 dB/100 m@250 MHz

Max. Attenuation

34.8 dB/100 m@250 MHz

Return Loss

≥17.3 dB/100 m@250 MHz

Mechanical

Tensile Strength

Sheath≥13.5 MPa, insulation≥16 MPa

Elongation at Break

Sheath≥150%, insulation≥300%

Installation Bending Radius

>8 times of outer cable diameter

Conductor Elongation at Break

≥10%

Environmental

Shrinkage of Insulation

≤5%

Color Migration Resistance of Insulation

No migration

Sheath Tensile Strength and Elongation at Break after Aging

≥12.5 MPa, ≥100%

Low Temperature Bending Test

No cracking after the test

Heat Shock Test

No cracking after the test

Operating Temperature

–20°C to +60°C (–4°F to 140°F)

Installation Temperature

0°C to +50°C (32°F to 122°F)

Storage Temperature and Humidity

–10°C to +40°C (14°F to 104°F), <60% (RH)

Security

Vertical Fire Propagation Test

Comply with IEC 60332-1-2

Packaging

Cable Length

305.0 m (1000.66 ft) ± 1.5 m (4.92 ft)

Inner Carton Dimensions

416.0 mm × 412.0 mm × 220.0 mm (16.37″ × 16.22″ × 8.66″) (L × W × H)

Packaging Method

305.0 m (1000.66 ft) a carton, one protection carton with 2 cartons inside

Net Weight

≥10.5 kg (23.15 lb)

Gross Weight

≥11.5 kg (25.35 lb)

Compliance

Executive Standards

Q/DXJ 067-2019, EN50575-2014

Certification

Certification

CPR Eca

Transmission Characteristics

(100 m at 20°C) (328.08 ft at 68°F)

Frequency (MHz)

Phase delay ≤ ns

IL ≤ dB

TCL≥ dB﹡

EL TCTL≥ dB﹡

NEXT ≥ dB

PS NEXT ≥ dB

1

n/s

n/s

50.0

35.0

n/s

n/s

4

552.0

4.0

44.0

23.0

66.3

63.3

8

547.0

5.6

41.0

16.9

61.8

58.8

10

545.0

6.4

40.0

15.0

60.3

57.3

16

543.0

8.1

38.0

10.9

57.2

54.2

20

542.0

9.0

37.0

9.0

55.8

52.8

25

541.0

10.1

36.0

7.0

54.3

51.3

30﹡

540.6

11.0

35.2

5.5

53.1

50.1

31.25

540.0

11.3

35.1

n/s

52.9

49.9

62.5

539.0

16.3

32.0

n/s

48.4

45.4

100

538.0

21.0

30.0

n/s

45.3

42.3

200

537.0

30.7

27.0

n/s

40.8

37.8

250

536.0

34.8

26.0

n/s

39.3

36.3

Frequency (MHz)

EL FEXT ≥ dB

PS EL FEXT ≥ dB

RL ≥ dB

Delay skew ≤ ns

Zc(Ω)

1

n/s

n/s

n/s

n/s

n/s

4

56.0

53.0

23.0

45.0

100±15

8

49.9

46.9

24.5

10

48.0

45.0

25.0

16

43.9

40.9

25.0

20

42.0

39.0

25.0

25

40.0

37.0

24.3

30﹡

38.5

35.5

23.8

31.25

38.1

35.1

23.6

62.5

32.1

29.1

21.5

100

28.0

25.0

20.1

200

22.0

19.0

18.0

250

20.0

17.0

17.3

Note:

Executive standard for the above parameters: Q/DXJ 067-2019

“n/s”=Not Specified

“﹡”=Unless otherwise customer stated the test results default to not shown in test report but comply with standard

Brand

Dahuaa

Documents

Reviews

There are no reviews yet.

Be the first to review “PFM920I-6UN-C”